Where are you now:Home / Products / Power secondary screens, cabinets, boxes

Power secondary screens, cabinets, boxes

RN-JLP secondary screen
  • RN-JLP secondary screen
  • RN-JLP secondary screen
  • RN-JLP secondary screen
  • RN-JLP secondary screen
RN-JLP secondary screen

1 Introduction to the device

The secondary AC power distribution panel is based on the Ministry of Energy "Power Plant, Substation Engineering and Relay Protection Test Instrument Configuration Quota" issued by the Ministry of Electric Power Industry "Power System Relay Protection and Safety Automatic Equipment Anti-accident Measures" Products designed and manufactured by relevant regulations. It provides a reliable, stable and convenient AC power supply for the work of the on-site secondary equipment, and provides a reliable guarantee for meeting the working power requirements of the on-site secondary equipment and ensuring the safety of personnel and equipment.

1.1 Purpose

This equipment is suitable for power plants, substations and large and medium-sized industrial enterprises, and can be used as a general-purpose AC power distribution panel for secondary equipment.

1.2 Features

1.2.1 It adopts dual power supply, which can be switched manually and automatically. The use of contactors can switch with load to ensure the reliability of power supply.

1.2.2 The control of AC power supply adopts high-breaking miniature circuit breaker, which has the advantages of rapid action, high sensitivity, reliable action, etc., and has the functions of short circuit and overload automatic tripping.

1.2.4 There are many feeders.

1.2.5 It has the function of short circuit and overload trip alarm indication.


2 Product structure

2.1 Screen body structure, surface coating, electrical clearance and creepage distance, anti-static measures, electrical performance, wire laying, temperature rise, heat resistance, mechanical performance and other requirements, all meet the requirements of the corresponding clauses of DL/T720-2000. A dedicated grounding copper bar with a cross-section of 100 square millimeters is installed in the screen.

2.2 Adopt PK-10 fully enclosed cabinet structure, front and rear doors with locks, and the screen body is made of plates. The screen structure diagram of the whole machine is shown in Figure 2.

2.3 Main internal components: automatic air switch, leakage protection switch, voltmeter, contactor, indicator light and other components.

2.4 The analog circuit is drawn on the screen to make it easy for the operator to identify and avoid misoperation;

2.5 The instrument, indicator light and control switch are installed on the front panel, and the input and output wires can be connected through the terminal block behind the screen.


3 Equipment electrical performance

3.1 Insulation resistance: Under standard test atmospheric conditions, the insulation resistance between each circuit of the device and the housing is not less than 10MΩ; the insulation resistance between each independent circuit is not less than 10MΩ.

3.2 Dielectric strength: Under standard test atmospheric conditions, the above-mentioned circuits and each independent circuit can withstand AC 50Hz, voltage 2kV (effective value), and the test lasts 1min without insulation breakdown or flashover.

3.3 Impulse voltage: Under standard test atmospheric conditions, each AC circuit and DC circuit should be able to withstand a standard lightning wave short-time impulse test of 5kV (peak).

3.4 The AC circuit uses Merlin Gerin C65N series small automatic switch, the mechanical life is more than 20,000 times on and off, and the instantaneous breaking current can reach (4~7) Ie.


4 Conditions of use

4.1 Use indoors with good indoor ventilation.

4.2 The altitude does not exceed 2000 meters.

4.3 Ambient air temperature: -10℃~+55℃.

4.4 Relative humidity: 5% to 95% (there is neither condensation nor freezing inside the device).

4.5 Vibration that exceeds the severity level 1 specified by IEC60255-21-1 shall not occur at the place of use.

4.6 The difference between the installation inclination and the plumb line is no more than 5. .

4.7 The place of use should have facilities to protect against rain, snow, wind and sand. The grounding resistance of the place of use should meet the requirements of 4.4 in GB/T 2887-2000 and the relevant requirements of the power system for lightning protection and grounding of the substation.


5 working principle

5.1 Electrical schematic diagram (see Figure 3)

5.2 Circuit introduction

5.2.1 The power input adopts three-phase four-wire 220V/380V dual-channel AC power supply, and the two power sources are automatically switched on each other.

5.2.2 The contactor to the busbar and the feeder output are equipped with high-breaking circuit breakers, which can facilitate the power-off maintenance of each circuit.

5.2.3 The voltmeter directly monitors the three-phase output voltage and reflects the power supply status. The plane simulation diagram is shown in Figure 4 and the terminal block diagram is shown in Figure 5.

5.2.4 Each feed switch has a set of trip alarm contacts, which can realize the alarm function.